home *** CD-ROM | disk | FTP | other *** search
Text File | 1993-07-15 | 21.8 KB | 1,009 lines |
- Recommendation X.10
- CATEGORIES OF ACCESS FOR DATA TERMINAL EQUIPMENT (DTE)
- TO PUBLIC DATA TRANSMISSION SERVICES
- (Malaga-Torremolinos, 1984; amended at Melbourne, 1988)
- The CCITT,
- considering
- (a) that Recommendation X.1 defines the international user classes of
- service in public data networks (PDNs) and ISDN;
- (b) that Recommendation X.2 defines the international user services and
- facilities in PDNs;
- (c) that Recommendation X.3 defines the Packet Assembly/Disassembly
- facility (PAD) in packet switched public data networks;
- (d) that Recommendation I.411 defines the reference configurations for
- access to ISDN services, including Terminal Adaptor (TA) functional grouping;
- (e) that Recommendations X.30 (I.461), X.31 (I.462) and the I.230 series,
- define the circuit switched and packet switched data transmission services
- available from ISDN (including through Terminal Adaptors);
- (f) the desirability for the users to have defined the various
- possibilities and requirements for accessing the different public data
- transmission services,
- unanimously recommends
- that categories of access for data terminal equipment (DTE) to the data
- transmission services provided by PDNs and by ISDNs through Terminal Adaptors
- should be as defined in this Recommendation.
- 1 Scope
- This Recommendation defines the different categories of access for data
- terminal equipment to the different data transmission services provided by public
- data networks (PDNs) as defined in Recommendation X.2 and by ISDNs (including
- through Terminal Adaptors) as defined in Recommendations X.30 (I.461) X.31
- (I.462) and the I.230 series, namely:
- i) circuit switched data transmission services;
- ii) packet switched data transmission services;
- iii) leased circuit data transmission services.
- The categories of access described in this Recommendation take into
- account direct connections (see Note) to public data networks and ISDNs and the
- various access cases where interworking with other public networks is involved.
- Access to the packet switched data transmission service via the PAD function as
- defined in Recommen-dation X.3 is also covered in this Recommendation.
- Note - Direct connections may be provided by means of leased circuits or
- by dedicated access circuits.
- 2 General
- Access for data terminal equipment to data transmission services may be
- achieved by either of the following (see Note):
- a) by direct connection of the DTE to the public data network or ISDNs;
- b) or by switched connection of the DTE to a PDN via an intermediate
- public network of another type (including a PDN, PSTN or ISDN);
- c) or by switched connection of the DTE to an ISDN (including through a
- Terminal Adaptor) via an intermediate public network of another type.
- For example, packet mode terminals may access the public packet switched
- data transmission service, in user classes of service 8 to 11, either directly or
- via a switched connection. The switched connection will be established using a
- circuit switched data network or a public switched telephone network. In both
- switched cases an interworking function will be required to access the packet
- switched data transmission service.
- Note - It is not mandatory for Administrations to provide all the
- categories of access contained in this Recommendation.
- 3 Categories of access
- S 3.1 specifies the categories of access to the data transmission services
- provided by PDNs for the direct connection case.
- S 3.2 specifies the categories of access to the data transmission services
- provided by PDNs for the switched connection case.
- S 3.3 specifies the categories of access to the data transmission services
- provided by ISDNs through Terminal Adaptors for the direct connection case.
- S 3.4 specifies the categories of access to the data transmission services
- provided by ISDNs through Terminal Adaptors for the switched connection case.
-
-
-
-
- Fascicle VIII.2 - Rec. X.10 PAGE1
-
- 3.1 Direct connection to data transmission services provided by public data
- networks
- TABLE 1/X.10
- Start-stop direct connection to a circuit switched data transmission service (see Notes 1
- and 2)
- Category of Data signalling DTE/DCE interface
- access rate requirements
- A1 50 to 200 bit/s See Recommendations X.20 and
- A2 300 bit/s X.20 bis
- TABLE 2/X.10
- Synchronous direct connection to a circuit switched
- data transmission service
- (see Note 1)
- Category of Data signalling DTE/DCE interface
- access rate requirements
- B1 600 bit/s
- B2 2 400 bit/s
- B3 4 800 bit/s See Recommendations X.21 and
- X.21 bis
- B4 9 600 bit/s
- B5 48 000 bit/s
- B6 64 000 bit/s
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- PAGE8 Fascicle VIII.2 - Rec. X.10
-
- TABLE 3/X.10
- Start-stop direct connection to a packet switched
- data transmission service
- (see Notes 1 and 2)
- Category of Data signalling DTE/DCE interface
- access rate requirements
- C1 110 bit/s
- C2 200 bit/s
- C3 300 bit/s See Recommendation X.28
- C4 200 bit/s
- C5 75/1 200 bit/s
- C6 2 400 bit/s
- TABLE 4/X.10
- Synchronous direct connection to a packet switched
- data transmission service
- (see Note 1)
- Category of access Data signalling rate DTE/DCE interface
- requirements
- D1 2 400 bit/s
- D2 4 800 bit/s See Recommendations X.25
- and X.31
- D3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Fascicle VIII.2 - Rec. X.10 PAGE1
-
- 9 600 bit/s (case A)
- D4 48 000 bit/s (see Note 3)
- D5 64 000 bit/s
- TABLE 5/X.10
- Start-stop direct connection to a leased circuit
- data transmission service
- (see Note 2)
- Category of Data signalling DTE/DCE interface
- access rate requirements
- E1 50 to 200 bit/s See Recommendations X.20 and
- E2 300 bit/s X.20 bis
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- PAGE8 Fascicle VIII.2 - Rec. X.10
-
- TABLE 6/X.10
- Synchronous direct connection to a leased circuit
- data transmission service
- Category of Data signalling DTE/DCE interface
- access rate requirements
- F1 600 bit/s
- F2 2 400 bit/s
- F3 4 800 bit/s See Recommendations X.21 and
- X.21 bis
- F4 9 600 bit/s
- F5 48 000 bit/s
- 3.2 Switched connection to data transmission services provided by public data
- networks
- TABLE 7/X.10
- Synchronous switched connection by means of the PSTN
- to a circuit switched data transmission service
- For further study.
- TABLE 8/X.10
- Start-stop switched connection by means of a CSPDN
- to a packet switched data transmission service
- Category of Data signalling DTE/DCE interface
- access rate requirements
- K1 300 bit/s See Recommendation X.28
- TABLE 9/X.10
- Start-stop switched connection by means of the PSTN
- to a packet switched data transmission service
- Category of Data signalling DTE/DCE interface
- access rate
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Fascicle VIII.2 - Rec. X.10 PAGE1
-
- requirements
- L1 110 bit/s
- L2 200 bit/s
- L3 300 bit/s See Recommendation X.28
- L4 200 bit/s
- L5 75/1 200 bit/s
- L6 2 400 bit/s
- TABLE 10/X.10
- Synchronous switched connection by means of a CSPDN
- to a packet switched data transmission service
- Category of access Data signalling rate DTE/DCE interface
- requirements
- O1 2 400 bit/s
- O2 4 800 bit/s
- O3 9 600 bit/s See Recommendation X.32
- O4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- PAGE8 Fascicle VIII.2 - Rec. X.10
-
- 48 000 bit/s
- O5 64 000 bit/s
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Fascicle VIII.2 - Rec. X.10 PAGE1
-
- TABLE 11/X.10
- Synchronous switched connection by means of the PSTN
- to a packet switched data transmission service
- Category of access Data signalling rate DTE/DCE interface
- requirements
- P1 1 200 bit/s
- P2 2 400 bit/s
- P3 4 800 bit/s See Recommendation X.32
- P4 9 600 bit/s
- TABLE 12/X.10
- Synchronous switched access by means of an ISDN B channel
- to a packet switched data transmission service
- Category of access Data signalling DTE/DCE interface requirements at
- rate
- Reference point S/T Reference point R
- Q1 2 400 bit/s
- Q2 4 800 bit/s See Recommendation
- X.31
- Q3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- PAGE8 Fascicle VIII.2 - Rec. X.10
-
- 9 600 bit/s (case A) See Recommendation
- X.32
- Q4 48 000 bit/s and Recommendation
- X.32
- Q5 64 000 bit/s
- 3.3 Direct connection to data transmission services provided by ISDNs
- (including through Terminal Adaptors)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Fascicle VIII.2 - Rec. X.10 PAGE1
-
- TABLE 13/X.10
- Synchronous direct connection to a circuit switched
- data transmission service
- Category of access Data signalling DTE/DCE interface requirements at
- rate
- Reference point S/T Reference point R
- S1 600 bit/s
- S2 2 400 bit/s
- S3 4 800 bit/s See Recommendation See Recommendations
- X.30 X.21 and X.21 bis
- S4 9 600 bit/s
- S5 48 000 bit/s
- S6 64 000 bit/s
- TABLE 14/X.10
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- PAGE8 Fascicle VIII.2 - Rec. X.10
-
- Synchronous direct connection via the ISDN B channel
- to a packet switched data transmission service
- Category of access Data signalling DTE/DCE interface requirements at
- rate
- Reference point S/T Reference point R
- T1 2 400 bit/s
- T2 4 800 bit/s See Recommendation See Recommendation
- X.31 (case B) X.25
- T3 9 600 bit/s
- T4 48 000 bit/s
- T5 64 000 bit/s
- TABLE 15/X.10
- Synchronous direct connection via the ISDN D channel
- to a packet switched data transmission service
- Category of access Data signalling DTE/DCE interface requirements at
- rate
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Fascicle VIII.2 - Rec. X.10 PAGE1
-
- Reference point S/T Reference point R
- U1 2 400 bit/s
- U2 4 800 bit/s
- U3 9 600 bit/s
- U4 . 48 000 bit/s (see See Recommendation See Recommendation
- Note 4) X.31 X.25
- U5 64 000 bit/s (see
- Note 4)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- PAGE8 Fascicle VIII.2 - Rec. X.10
-
- 3.4 Switched connection to data transmission services provided by ISDNs
- (including through Terminal Adaptors)
- TABLE 16/X.10
- Start-stop switched connection by means of the PSTN
- to a packet switched data transmission service
- For further study.
- TABLE 17/X.10
- Synchronous switched connection by means of a CSPDN
- to a packet switched data transmission service
- For further study.
- TABLE 18/X.10
- Synchronous switched connection by means of the PSTN to a packet switched data
- transmission service
- For further study.
- TABLE 19/X.10
- Synchronous switched connection by means of an ISDN B channel
- to a packet switched data transmission service
- Category of access Data signalling DTE/DCE interface requirements at
- rate
- Reference point S/T Reference point R
- Y1 2 400 bit/s
- Y2 4 800 bit/s
- Y3 9 600 bit/s See Recommendation See Recommendation
- X.31 (case B) X.25
- Y4 48 000 bit/s
- Y5 64 000 bit/s
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Fascicle VIII.2 - Rec. X.10 PAGE1
-
-
- Note 1 - Direct connections may be provided by means of leased circuits or by dedicated
- access circuits.
- Note 2 - Some Administrations may offer the categories of access of 600 bit/s, 1200
- bit/s, 2400 bit/s, 4800 bit/s and 9600 bit/s.
- Note 3 - Recommendation X.31 (case A) is appropriate at the S/T reference point when
- category of access D5 is provided by means of ISDN B channel.
- Note 4 - For 64 kbit/s D channel only.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- PAGE8 Fascicle VIII.2 - Rec. X.10
-
-